SiMPLE sYsTEM MoDELs

The equations presented in this chapter can be combined and used to model the whole system. The model includes all physical components of the system, such as the collector, storage tank, heat exchanger, loads, and heat losses from the system components, such as pipes and storage tank. Detailed models result in a set of coupled algebraic and differential equations, with time as the independent variable. The inputs to these equations are meteorological data and load variations (e.g., water draw-off profile). The time step for such a model is usually 1 h, and for annual calculations, a computer is required. More details on these models are given in Chapter 11. In this section, we deal with only simple models that can be solved by hand calculations or the help of a spreadsheet.

A simple model considers a fully mixed or unstratified storage tank supplying hot water at a fixed flow rate and a make-up water constant temperature, Tmu. Therefore, by ignoring pipe losses and considering that the storage tank is at a uniform temperature, Ts, Eq. (5.31) for the storage tank can be combined with Eq. (4.3) for the collector and Eq. (5.32) for the storage tank losses, to give

(Mcpl-^ = AcFr[S - UL(T - Ta)]+ - eL(rnLcp)mm(Ts - Tmu)

The middle term of the right-hand side in this equation is the energy delivered to the load through a load heat exchanger, which has an effectiveness eL. If no load heat exchanger is used, the term eL(rhLcp)min is replaced by mLcp, where in both cases hnL is the load flow rate. This is, in fact, the same as Eq. (5.31) but with the various terms inserted in the equation.

To solve this equation, the collector parameters, storage tank size and loss coefficient, the effectiveness and mass flow rate of the heat exchanger, and the meteorological parameters are required. Once these are specified, the storage tank temperature can be estimated as a function of time. Additionally, the individual parameters, such as the useful energy gain from the collector and the losses from the storage tank, can be determined for a period of time by integrating the appropriate quantities. To solve Eq. (5.68), the simple Euler integration method can be used to express the temperature derivative dTs/dt as (Ts-n-Ts)/At. This is similar to writing the equation in finite difference form, as indicated in Section 5.3.2. Therefore, Eq. (5.68) can be expressed as a change in storage tank temperature for the time period required as

- £L (mLCp )min (Ts - Tmu) - (UA)s (Ts ~ Ta)J (5.69)

The only caution required in using this integration scheme is to choose a small time step to ensure stability. Because meteorological data are available in hour increments, a time step of 1 h is also used in solving Eq. (5.69) if stability is kept. A good verification of the calculations is to check the energy balance of the tank by estimating the change of internal energy of the water, which must be equal to the summation of the useful energy supplied by the collector minus the summation of the energy to load and energy lost. In equation form,

where

Ts, i = initial storage tank temperature (°C). Ts, f = final storage tank temperature (°C).

Problems for this kind of analysis are similar to Examples 5.2 and 5.3. In those examples, the load was considered to be known, whereas here it is calculated by the middle term of Eq. (5.69).

Was this article helpful?

0 0
Solar Panel Basics

Solar Panel Basics

Global warming is a huge problem which will significantly affect every country in the world. Many people all over the world are trying to do whatever they can to help combat the effects of global warming. One of the ways that people can fight global warming is to reduce their dependence on non-renewable energy sources like oil and petroleum based products.